Description
| Features: |
|
|---|---|
| Classification: | AWS A5.22 E309LT0-1/4 |
| Shielding gas: | CO2 or Ar-CO2 |
| Polarity: | DCEP |
Packaging data
| φ mm | Spool |
|---|---|
| 1.2 | 12.5kg |
| Volume mm | 295W, 110H, 295L |
Composition (wire mass%)
| Typical (Ar-CO2) | Guarantya |
|
|---|---|---|
| C | 0.03 | 0.04 |
| Si | 0.8 | 1.0 |
| Mn | 1.1 | 0.5~2.5 |
| P | 0.02 | 0.04 |
| S | <0.01 | 0.03 |
| Ni | 12.4 | 12.0~14.0 |
| Cr | 24.1 | 22.0~25.0 |
| Mo | 0.03 | 0.75 |
| Cu | 0.03 | 0.75 |
| Note: aSingle values are maximium. |
||
Welding parameters (A)
| φ mm | 1F, 1G, 2F | 2G |
|---|---|---|
| 1.2 | 130~270 | 150~220 |
All-weld mechanical properties
| Typical (Ar-CO2) | Guaranty | |
|---|---|---|
| 0.2%YS (MPa) | 454 | - |
| TS (MPa) | 608 | 518min. |
| El on 4d (%) | 32 | 30min. |
Approvals / Click here for certificates
| CWB | E309LT0-1, E309LT0-4 |
|---|